background image

Electrical System Quick Checks

Battery Test (Open Circuit Test)

Use a multimeter to measure the voltage between the
battery terminals.

Set multimeter to the DC volts setting. The battery
should be at a temperature of 60 to 100

_

F (16 to 38

_

C).

The ignition key should be off and all accessories turned
off. Connect the positive (+) meter lead to the positive
battery post and the negative (–) meter lead the the neg-
ative battery post.

NOTE: This test provides a relative condition of the bat-
tery. Load testing of the battery will provide additional
and more accurate information.

Voltage Measured

Battery Charge Level

12.68 V (or higher)

Fully charged (100%)

12.45 V

75% charged

12.24 V

50% charged

12.06 V

25% charged

11.89 V

0% charged