Toro Sand Pro 5020 User Manual

Page 142

Advertising
background image

E. Connect a battery load tester to the battery ter-
minals following the manufacturer’s instruc-
tion
s. Connect a digital multimeter to the battery
terminals.

F. Apply a test load of one half the Cranking Perfor-
mance (see Battery Specifications) rating of the bat-
tery for 15 seconds.

G. Take a voltage reading at 15 seconds, then re-
move the load.

H. Using the table below, determine the minimum
voltage for the cell temperature reading.

Minimum

Voltage

Battery Electrolyte

Temperature

9.6

70

_

F (and up)

21.1

_

C (and up)

9.5

60

_

F

15.6

_

C

9.4

50

_

F

10.0

_

C

9.3

40

_

F

4.4

_

C

9.1

30

_

F

–1.1

_

C

8.9

20

_

F

–6.7

_

C

8.7

10

_

F

–12.2

_

C

8.5

0

_

F

–17.8

_

C

I. If the test voltage is below the minimum, replace
the battery. If the test voltage is at or above the mini-
mum, return the battery to service.

Installation (Fig. 10 and 11)

IMPORTANT: To prevent possible electrical prob-
lems, install only a fully charged battery.

1. Make sure ignition switch and all accessories are
off.

2. Make sure battery compartment is clean and re-
painted if necessary.

3. Make sure all battery cables and connections are in
good condition and battery clamp or hold down has
been repaired or replaced.

4. Place battery in its compartment. Make sure battery
is level and flat. Connect positive cable connector onto
positive battery post. Tighten cap screw and lock nut
with two wrenches.

5. Secure battery clamp or hold down to the battery
and hold down rod with the washer and wing nut. Do not
overtighten to prevent cracking or distorting the battery
case.

6. Apply a light coat of grease on all battery posts and
cable connectors to reduce corrosion after connections
are made.

7.

Connect a digital multimeter (set to amps) between

the negative battery post and the negative (ground)
cable connector. The reading should be less than 0.1
amp. If the reading is 0.1 amp or more, the unit’s electri-
cal system should be tested and repaired.

8. Connect negative (ground) cable connector to the
negative battery post. Tighten cap screw and lock nut
with two wrenches.

Charging

To minimize possible damage to the battery and allow
the battery to be fully charged, the slow charging meth-
od is presented here. This charging method can be ac-
complished with a constant current battery charger
which is available in most shops.

CAUTION

Follow the manufacturer’s instructions when us-
ing a battery charger.

NOTE: Using specific gravity of the battery cells is the
most accurate method of determining battery condition.

1.

Determine the battery charge level from either its

open specific gravity or circuit voltage.

Battery Charge

Level

Specific

Gravity

Open Circuit

Voltage

100%

1.265

12.68

75%

1.225

12.45

50%

1.190

12.24

25%

1.155

12.06

0%

1.120

11.89

Electrical Systems

Page 5 – 16

Sand Pro 2020/3020/5020

Advertising
This manual is related to the following products: