Hour meter – Toro Sand Pro 5020 User Manual

Page 137

Advertising
background image

Hour Meter

IMPORTANT: Make sure to observe polarity on the
meter label when testing. Damage to the meter may
result from an improper connection.

1. Connect the positive (+) terminal of a 12 VDC
source to the positive terminal of the hour meter.

2. Connect the negative (–) terminal of the voltage
source to the other terminal of the hour meter.

3. The hour meter should move a 1/10 of an hour in six
minutes.

SP 2020/3020

4. Disconnect the voltage source from the hour meter.

Figure 6

WINDOW

1/10 WHEEL: WHITE W/BLACK NUMBERS
HOUR WHEELS: BLACK W/WHITE NUMBERS

1

10

HOURS

0 0 0 0 0

RUNNING: INDICATOR

QUARTZ

SP 5020

Figure 7

Sand Pro 2020/3020/5020

Page 5 – 11

Electrical Systems

Electrical

Systems