Check interlock system, Warning – Toro Sand Pro 5020 User Manual

Page 143

Advertising
background image

2. Determine the charging time and rate using the
manufacturer’s battery charger instructions
or the
following table.

Battery

Battery Charge Level

Reserve

(Percent of Fully Charged)

Capacity

Capacity

(Minutes)

75%

50%

25%

0%

80 or less

3.8 hrs

7.5 hrs

11.3 hrs

15 hrs

@

@

@

@

3 amps

3 amps

3 amps

3 amps

81 to 125

5.3 hrs

10.5 hrs 15.8 hrs

21 hrs

@

@

@

@

4 amps

4 amps

4 amps

4 amps

126 to

5.5 hrs

11 hrs

16.5 hrs

22 hrs

170

@

@

@

@

5 amps

5 amps

5 amps

5 amps

171 to

5.8 hrs

11.5 hrs 17.3 hrs

23 hrs

250

@

@

@

@

6 amps

6 amps

6 amps

6 amps

above

6 hrs

12 hrs

18 hrs

24 hrs

250

@

@

@

@

10 amps 10 amps 10 amps 10 amps

CAUTION

60

_

F (15.5

_

Charge the battery in a well–ventilated place to
dissipate gases produced from charging. These

Nausea may result if the gases are inhaled. Un-
plug the charger from the electrical outlet before

from the battery posts.

Do not charge a frozen battery because it can ex-
plode and cause injury. Let the battery warm to

C) before connecting to a charger.

gases are explosive; keep open flame and elec-
trical spark away from the battery. Do not smoke.

connecting or disconnecting the charger leads

3. Following the manufacturer’s instructions, con-
nect the charger cables to the battery. Make sure a good
connection is made.

4. Charge the battery following the manufacturer’s
instructions
.

5. Occasionally check the temperature of the battery
electrolyte. If the temperature exceeds 125

_

F (51.6

_

C)

or the electrolyte is violently gassing or spewing, the
charging rate must be lowered or temporarily stopped.

6. Three hours prior to the end of the charging, mea-
sure the specific gravity of a battery cell once per hour.
The battery is fully charged when the cells are gassing
freely at a low charging rate and there is less than a
0.003 change in specific gravity for three consecutive
readings.

protection, so do not disconnect it. Check

lock system operation. If the switch is defec-
tive, replace it before operating. Whether the

not rely entirely on safety switches – use good
judgement!

WARNING

The interlock switch is for the operator’s

switch operation daily to assure proper inter-

switch is operating properly or not, replace it
every two years to assure maximum safety. Do

Check Interlock System

The purpose of the interlock system is to prevent the en-
gine from cranking or starting unless the traction pedal
is in “NEUTRAL”.

1. Check interlock operation in a wide open area free
of debris and bystanders. Stop engine.

2. Sit on the seat. Depress traction pedal in forward
and reverse directions, while trying to start the engine in
each position. If the engine cranks with the pedal in ei-
ther the forward or reverse position, there may be a mal-
function in the interlock system. Repair problem
immediately. If the engine does not crank, the system is
operating correctly.