7. Remove three cap screws securing the pump plate
to the hydrostat while pulling the pump plate from the hy-
drostat (Fig. 32).

8. Clean all hydraulic fittings and hydraulic hoses at-
tached to the hydrostat. Label all hydraulic connections
for reassembly.

9. Place a suitable container under hydrostat to collect
hydraulic oil.

10. Clamp suction hose (8) to prevent draining the hy-
draulic tank.

11. Remove hydraulic hoses (11 and 14) from 90

o

hy-

draulic fittings (13 and 12). Allow fluid to drain from the
hoses into the container.

12. Remove suction hose (8) from push on fitting (10).
Allow fluid to drain from the hose into the container.

13. Remove hydraulic hoses (4 and 5) and O–rings (29)
from the hydrostat. Allow fluid to drain from the hoses
into the container.

14. Put caps or plugs on disconnected hoses and fit-
tings to prevent contamination.

15. Loosen both set screws (20) from hydrostat shaft.

16. Support hydrostat to prevent dropping during re-
moval. Remove both hex nuts (27), lock washers (28),
cap screws (6) from the hydrostat (9) and pump mount
(25). Pull hydrostat from mount and machine.

17. Remove woodruff key (26) from hydrostat shaft.

18. Match mark position of hydraulic fittings on the hy-
drostat. Remove remaining fittings (10, 12, and 13) and
O–rings (31 and 32) from the hydrostat. insert caps or
plugs into open ports of the hydrostat.

Installation (Fig. 31)

1. Make sure lift valve, hydraulic hoses, fittings, and
tubes are cleaned thoroughly.

2. Reinstall O–rings (32) and hydraulic fittings (12 and
13) to the hydrostat. Observe match marks when tight-
ening.

3. Remove caps or plugs from the hydrostat.

4. Install woodruff key (26) to hydrostat shaft. Support
hydrostat (9) while positioning onto pump mount (25).
Make sure woodruff key (26) stays in place when the
shaft is inserted into the pump hub (24).

5. Secure hydrostat to mount with both cap screws (6),
lock washers (28), hex nuts (27). Tighten set screw (20)
to hydrostat shaft.

6. Remove caps and plugs from disconnected hoses
and fittings.

7. Reinstall hydraulic hoses (11 and 14) to 90

o

hydrau-

lic fittings (13 and 12).

8. Reinstall hose clamp (30) and suction hose (8) to
push on fitting (10). Tighten hose clamp.

9. Remove clamp used to prevent draining the hydrau-
lic tank from suction hose (8).

10. Reinstall hydraulic hoses (4 and 5) and O–rings (29)
to hydrostat (9).

11. Secure pump plate to the hydrostat with three cap
screws. Tighten cap screws while attaching the pump
plate to the hydrostat (Fig. 32).

12. Align pump lever to the hydrostat trunnion. Secure
pump lever to the hydrostat trunnion with cap screw and
lock nut (Fig. 32).

13. Reconnect wires to the neutral switch (Fig. 32).

14. Insert control rod into the pump lever. Secure pump
control rod to the pump lever with flat washer and cotter
pin (Fig. 32).

15. Secure muffler shield to the engine with three cap
screws and lock star washers securing. Make sure R–
clamp and fuel hose a secured to the muffler shield by
cap screw and lock star washer.

16. Secure cover to the midsection of the machine and
pivot seat down.

17. Charge hydraulic system (see Charge Hydraulic
System).

5

1

2

3

4

Figure 32

1. Control

rod

4. Neutral

switch

2. Pump

lever

5. Pump

plate

3. Wires