Adding components to the terminal module, 54 field wiring chapter 2, Figure 2-17. additional component location – VXI VT1422A User Manual

Page 54: Figure 2-18. series & parallel component examples, Default circuit, Normal mode low-pass filter circuit

Advertising
background image

54 Field Wiring

Chapter 2

Adding Components to the Terminal Module

The back of the terminal module PCB (printed circuit board) provides surface mount
pads which can be used to add serial and parallel components to any channel's signal
path. Figure 2-17 shows additional component locator information (see the
schematic and pad layout information on the back of the terminal module PCB).
Figure 2-18 shows some usage example schematics.

Upper layout also applies here

Upper layout also applies here

Lower layout also applies here

Lower layout also applies here

SCHEMATIC OF MODIFIABLE PARTS

HI

HI

LO

LO

TO VT1413C/VT1415A

SH

SL

COMP

LOCATOR

COMP

LOCATOR

Figure 2-17. Additional Component Location

TO VT1422A

LO

HI

TO USER WIRING

PH
L

PH

PL

0 ohms

0 ohms

LO

HI

Default Circuit

SH

SL

PHL

LO

HI

TO VT1422A

SH

LO

HI

PH

PL

SL

10 kohms

10 kohms

Normal Mode Low-Pass Filter Circuit

TO USER WIRING

LO

HI

SH

0 ohms

SL

0 ohms

PH
L

250

ohm

s

or

200

ohm

s

TO VT1422A

HI

LO

PH

PL

4-20 mA NOTE: input must not exceed common mode limits (usually

±16 volts unless attenuated with a VT1513A SCP)

4 to 20 mA Sense

5 V full scale with 250 ohm (must use 16 volt range)
4 V full scale with 200 ohm (can use 4 volt range for better resolution)

0.

1

F

µ

Figure 2-18. Series & Parallel Component Examples