Troubleshooting Tips

Table 5-1 provides some general guidelines for troubleshooting problems you may
encounter with the Vision 65/75. If the suggested solutions fail to resolve the problem or if
you encounter an issue not described here, please contact Vidikron Technical Support.

Table 5-1. Troubleshooting Chart

Symptom

Possible Cause(s)

Solution

The projector does not turn on.

•

The Vision 65/75 is not
plugged in or the AC outlet
is not active.

•

The main power switch (at
the rear of the projector) is
off.

•

Lamp cover is not securely
attached.

•

Ensure that the Vision
65/75 is plugged in and
that the AC outlet is active.

•

Turn on the power switch.

•

Securely attach the lamp
cover.

The projector does not turn
back on after it was powered
off.

•

The projector will not turn
on for two minutes after
power-off, to protect the
lamp.

•

Wait until the Vision 65/75
completes its cool-down
(POWER LED lights solid
orange).

The remote control does not
work correctly.

•

The batteries have run out.

•

Replace the batteries.

The projector is on and OSD
menus appear, but there is no
video image on-screen.

•

Incorrect source selection.

•

Source component is not
turned on.

•

Source component is
connected incorrectly or
not at all.

•

Select the correct source.

•

Turn on the source.

•

Check cable connection
from source component to
projector.

A projected image from a DVD
is split or otherwise scrambled.

•

DVD player is connected to
the Component input and
set to progressive scan
mode.

•

Turn off progressive scan
on the DVD player.

Image is blurred.

•

The lens is not correctly
focused.

•

Adjust the focus with the
remote control.

Image is too bright and/or
lacks definition in the bright
areas of the image.

•

Contrast is set too high.

•

Lower the contrast setting.

Image appears “washed out”
and/or dark areas appear too
bright.

•

Brightness is set too high.

•

Lower the brightness
setting.

Colors in the image are
swapped; for example, reds
appear blue or vice versa.

•

The Red/Pr, Green/Y or
Blue/Pb outputs from the
source are connected to the
wrong inputs on the Vision
65/75.

•

Ensure that the source
outputs are connected to
the correct Vision 65/75
input.

POWER LED lights solid red.

•

Internal failure.

•

Please contact your
Vidikron dealer for
assistance.