ZyXEL Communications ZyXEL ZyWALL 2WG User Manual

Page 621

Advertising
background image

Chapter 46 Call Scheduling

ZyWALL 2WG User’s Guide

621

Once your schedule sets are configured, you must then apply them to the desired remote
node(s). Enter 11 from the Main Menu and then enter the target remote node index. Press
[SPACE BAR] and then [ENTER] to select PPPoE in the Encapsulation field to make the
schedule sets field available as shown next.

Figure 408 Applying Schedule Set(s) to a Remote Node (PPPoE)

You can apply up to four schedule sets, separated by commas, for one remote node. Change
the schedule set numbers to your preference(s).

Day

If you selected Weekly in the How Often field above, then select the day(s) when the

set should activate (and recur) by going to that day(s) and pressing [SPACE BAR] to

select Yes, then press [ENTER].

Start Time

Enter the start time when you wish the schedule set to take effect in hour-minute format.

Duration

The duration determines how long the ZyWALL is to apply the action configured in the

Action field. Enter the maximum length of time in hour-minute format.

Action

Forced On means that the connection is maintained whether or not there is a demand

call on the line and will persist for the time period specified in the Duration field.
Forced Down means that the connection is blocked whether or not there is a demand

call on the line.
Enable Dial-On-Demand means that this schedule permits a demand call on the line.
Disable Dial-On-Demand means that this schedule prevents a demand call on the line.

When you have completed this menu, press [ENTER] at the prompt “Press ENTER to Confirm…” to

save your configuration, or press [ESC] at any time to cancel.

Menu 11.1 - Remote Node Profile

Rem Node Name= ChangeMe Route= IP
Active= Yes

Encapsulation= PPPoE Edit IP= No
Service Type= Standard Telco Option:
Service Name= Allocated Budget(min)= 0
Outgoing= Period(hr)= 0
My Login= Schedules= 1,2,3,4
My Password= ******** Nailed-Up Connection= No
Authen= CHAP/PAP
Session Options:
Edit Filter Sets= No
Idle Timeout(sec)= 100


Press ENTER to Confirm or ESC to Cancel:

Table 245 Schedule Set Setup (continued)

FIELD