Xantrex Technology XTR 850 Watt User Manual
Xantrex Technology Tools
Advertising
This manual is related to the following products:
Table of contents
Document Outline
- Important Safety Instructions
- Introduction
- Installation
- Local Operation
- Introduction
- Configuring Settings from the Front Panel
- Navigating the Menu System
- Display Messages on the Front Panel
- Standard Operation
- Turning the Output On/Off
- Turning the Auxiliary Output On/Off
- Output Auto Start Mode (Auto Restart)
- Auxiliary Auto Start Mode
- Alarms and Errors
- Setting Foldback Mode
- Using Over Voltage Protection (OVP)
- Using Under Voltage Protection (UVP)
- Over Current Protection (OCP)
- Using Over Temperature Protection Lock (OTP)
- Current Configuration Memory Settings
- User Setting Memory Locations
- Local Lockout
- Using the External Shutdown Function
- Interlock Function
- Hardware Malfunction Alarms
- Resetting the Power Supply
- Using Multiple Power Supplies
- Analog Programming (APG) and Isolated Analog Programming (ISOL)
- Introduction
- Analog Programming Mode
- Isolated Analog Programming Mode (ISOL)
- Voltage and Current Readback (Isolated)
- Remote Operation
- Introduction
- Hardware and Connection Setup
- Configuring Remote Control Using RS-232
- Configuring Remote Control Using RS-485
- Configuring Remote Control using the USB Connector
- Setting Up the PC to Use the USB Connection
- Ethernet (ENET) or GPIB Connector (Optional)
- Multiple Power Supply Connections to RS-485 Bus
- Multiple Power Supply Connections to ENET
- Terminal Configuration
- Status Registers Model from IEEE 488.2
- Status Byte
- Standard SCPI Register Structure
- OPERation Status Register
- QUEStionable Status Register
- SCPI Error/Event Queue
- Locking and Unlocking the Front Panel
- Configure Other Protection Mechanisms
- Calibration and Troubleshooting
- Introduction
- Main Voltage and Current Calibration Principle
- Calibrating the Output Voltage
- Calibrating the Output Current
- Over Voltage Protection Calibration
- Non-isolated Analog Programming Calibration
- Non-isolated Voltage Monitoring Calibration
- Non-isolated Current Monitoring Calibration
- Non-isolated Voltage Programming of Voltage Calibration
- Non-isolated Resistive Programming of Voltage Calibration
- Non-isolated Voltage Programming of Current Calibration
- Non-isolated Resistive Programming of Current Calibration
- Calibration Procedure for Isolated Modes
- Storing and Loading Calibration Parameters
- Restore Factory Calibration
- User Diagnostics
- SCPI Command Reference
- Error Messages
- Specifications
- Warranty and Product Information
- Index