975-0545-01-01

37

Configuration

Batt Type

Full name

Battery Type

Configurable setting

Select the type of battery from flooded, custom,

AGM, or gel. If a battery temperature sensor is not present, the Freedom
SW 3000 uses the hot setting which is the default value, unless the setting
has been adjusted during configuration.

When to use

This setting is adjusted for the type of battery you have. It is

important during installation to choose the correct setting (battery type) to
optimize the charge algorithm for your battery and to properly enable or
disable equalization. See “Battery Charging Reference” on page 55.

The custom setting is selected to get the battery settings programmed by the
dealer.

Batt Size

Full name

Battery size

Configurable setting

This features let you select the size of the battery

bank being charged.

You can adjust the Battery Size settings as follows:

When to use

Adjust this setting to your actual battery bank size.

Outcome

Reduces the maximum charger current to protect against

charging smaller batteries too aggressively. This setting charges batteries
appropriately based on capacity. (See the Battery Information section in the
FSW3000 Sine Wave Inverter/Charger Installation Guide for more
information.)

Clear Faults

Purpose

Clear Faults is a command which clears all active faults in the

Freedom SW 3000. When faults are cleared, the device will resume normal
operation. If the fault condition still exists, the fault will reoccur. See

“Fault

Types” on page 45

for an explanation of faults.

You can adjust the Clear Faults settings as follows:

Batt Type

[Flooded]

Batt Size

[440 Ah]

Range of values

Increment

Default

50 Ah to 2000 Ah

10 Ah

440 Ah

Clear Faults

Value

Effect

Yes

Faults are cleared

No

No action