Battery charger interruption – Xantrex Technology FREEDOM SW 3000 User Manual

Page 74

Advertising
background image

60

Freedom SW 3000 Owner’s Guide

Battery Charging Reference

Battery Charger Interruption

If battery charging is interrupted in bulk charge (for example, AC is
disconnected, or a fault occurs), the unit will return to bulk charge when
battery charging resumes.

If battery charging is interrupted in any stage other than bulk, the unit will
go to float charge when battery charging resumes.

However, a new bulk charge cycle is initiated when battery charging begins,
if:

the battery drops below 12.5 Vdc for 15 minutes (V

F2

) i.e., the

15-minute countdown is independent of mode: for example, inverting,
bulk charging, or float charging, and

7 days have passed from the time the charger completed Absorption
(

ΔT

F

).

Advertising