Xantrex Technology FREEDOM SW 3000 User Manual

Page 62

Advertising
background image

48

Freedom SW 3000 Owner’s Guide

Troubleshooting

4.

If your Freedom SW 3000 or SCP is not displaying a Fault light, check
the following list to make sure that the present state of the installation
allows proper operation of the unit:

Is the inverter/charger located in a clean, dry, adequately ventilated
place?

Have the AC input breakers opened? If so, your pass through load may
have exceeded the rating of one or more of the input breakers.

Are the battery cables adequately sized and short enough?

Is the battery in good condition and are all DC connections tight?

Are the AC input and output connections and wiring in good
condition?

Are the configuration settings correct for your particular installation?

Are the display panel and the communications cable properly
connected and undamaged?

Is the battery temperature sensor and its cable properly connected and
undamaged?

5.

Contact Xantrex Customer Service for further assistance. Please be
prepared to describe details of your system installation and provide the
model and serial number of the unit. See “Contact Information” on
page v for
contact information.

Advertising