SYSTEM STATUS

During G1000 power-up, TAWS conducts a self-test of its aural and visual annunciations. The system test can

also be manually initiated. An aural alert is issued at test completion. TAWS System Testing is disabled when
ground speed exceeds 30 knots.

Alert Type

PFD/MFD Alert

Annunciation

TAWS Page

Annunciation

Aural Message

System Test in Progress

TAWS TEST

None

System Test Pass

None

None

“TAWS System Test OK”

TAWS System Test Fail

TAWS FAIL

“TAWS System Failure”

Table 6-15 TAWS System Test Status Annunciations

Manually testing the TAWS System:

1)

Select the TAWS Page.

2)

Press the MENU Key.

3)

Select Test TAWS and press the ENT Key to confirm the selection.