System status, Hazard avoidance – Garmin G1000 Socata TBM 850 User Manual
Page 390
Garmin G1000 Pilot’s Guide for the Socata TBM 850
190-00709-01 Rev. A
378
HAZARD AVOIDANCE
SY
STEM
O
VER
VIEW
FLIGHT
INSTRUMENTS
EAS
AUDIO P
ANEL
& CNS
FLIGHT
MANA
GEMENT
HAZARD
AV
OID
ANCE
AFCS
ADDITIONAL FEA
TURES
APPENDICES
INDEX
SYSTEM STATUS
During G1000 power-up, TAWS conducts a self-test of its aural and visual annunciations. The system test can
also be manually initiated. An aural alert is issued at test completion. TAWS System Testing is disabled when
ground speed exceeds 30 knots.
Alert Type
PFD/MFD Alert
Annunciation
TAWS Page
Annunciation
Aural Message
System Test in Progress
TAWS TEST
None
System Test Pass
None
None
“TAWS System Test OK”
TAWS System Test Fail
TAWS FAIL
“TAWS System Failure”
Table 6-15 TAWS System Test Status Annunciations
Manually testing the TAWS System:
1)
Select the TAWS Page.
2)
Press the MENU Key.
3)
Select Test TAWS and press the ENT Key to confirm the selection.