APPENDIX A

GIA 63W MESSAGE ADVISORIES (CONT.)

Message

Comments

TRUE APR – True north approach.
Change HDG reference to TRUE.

Displayed after passing the first waypoint of a true north approach when the nav
angle is set to ‘AUTO’.

GPS1 SERVICE – GPS1 needs service.
Return unit for repair.

A failure has been detected in the GPS1 and/or GPS2 receiver. The receiver may still
be available. The G1000 system should be serviced.

GPS2 SERVICE – GPS2 needs service.
Return unit for repair.
NAV1 SERVICE – NAV1 needs service.
Return unit for repair.

A failure has been detected in the NAV1 and/or NAV2 receiver. The receiver may still
be available. The G1000 system should be serviced.

NAV2 SERVICE – NAV2 needs service.
Return unit for repair.
NAV1 RMT XFR – NAV1 remote
transfer key is stuck.

The remote NAV1 and/or NAV2 transfer switch is stuck in the enabled (or “pressed”)
state. Press the transfer switch again to cycle its operation. If the problem persists,
the G1000 system should be serviced.

NAV2 RMT XFR – NAV2 remote
transfer key is stuck.
G/S1 FAIL – G/S1 is inoperative.

A failure has been detected in glideslope receiver 1 and/or receiver 2. The G1000
system should be serviced.

G/S2 FAIL – G/S2 is inoperative.
G/S1 SERVICE – G/S1 needs service.
Return unit for repair.

A failure has been detected in glideslope receiver 1 and/or receiver 2. The receiver
may still be available. The G1000 system should be serviced when possible.

G/S2 SERVICE – G/S2 needs service.
Return unit for repair.

GEA 71 MESSAGE ADVISORIES

Message

Comments

GEA1 CONFIG – GEA1 config error.
Config service req’d.

The GEA1 configuration settings do not match those of backup configuration memory.
The G1000 system should be serviced.

GEA2 CONFIG – GEA2 config error.
Config service req’d.

The GEA2 configuration settings do not match those of backup configuration memory.
The G1000 system should be serviced.

MANIFEST – GEA1 software
mismatch, communication halted.

The #1 GEA 71 has incorrect software installed. The G1000 system should be
serviced.

MANIFEST – GEA2 software
mismatch, communication halted.

The #2 GEA 71 has incorrect software installed. The G1000 system should be
serviced.