PNEG-1556 8", 10" and 12" Commercial Vertical Drive Unit - Dual Drive

Horizontal Drive

Vertical Drive

A. A magnetic starter should be used for the operator’s protection and for the protection of the motor.

This is to protect the operator against accidental restart caused by power interruption, conductor
fault, low voltage, circuit interruption or motor overload. Therefore, the motor must be restarted
manually. If using a motor with built-in thermal overload protection, make sure this type of motor has
a manual reset.

Auger

Part #

Motor

Sheave

Size

Flight Sheave

NEMA Motor

Frame

Motor HP

Belt

Size

Belt

Quantity

Belt Type

Size

RPM

8''

CE-00566

3.5''

15''

409

182T and 184T 3-5 HP

56

2

B

GK1346

213T and 215T 7-1/2 - 10 HP

57

3

10''

MHC00743

3.75''

18.4"

357

184T

5 HP

65

2

BX

213T and 215T 7-1/2 - 10 HP

MHC00485

254T

15 HP

67

3

BX

12"

MHC00020

3.75''

18.4"

357

213T and 215T 7-1/2 - 10 HP

68

2

BX

MHC00486

254T and 256T 15-20 HP

70

3

Auger

Part #

Motor

Sheave

Size

Flight Sheave

NEMA Motor

Frame

Motor HP

Belt

Size

Belt

Quantity

Belt Type

Size

RPM

8''

GK1346

5.0''

15"

584

184T

5 HP

57

2

B

10''

GK4441

4.0''

15"

467

213T

7-1/2 HP

59

3

B

12''

MHC01253

3.5''

15"

409

215T

10 HP

62

3

BX

1750 RPM electric motors and controls shall be installed by a qualified
electrician and must meet the standards set by the National Electrical Code and
all local and state codes. Reset and motor starting controls shall be located
where the operator has unrestricted access to the controls.

Disconnect and lock out power before resetting motor overloads. Ensure
electric motors are grounded.