Gas Volume and Pressure

Natural gas supply should offer:

1. 49 MJ/m3 calorific value.

2. 650 mBar supply pressure. (Lower pressure may inhibit dryer performance.)

3. Gas pipework and controls from the supply to the dryer must be installed by the gas supplier in

accordance with local directives, laws, codes and regulations.

Check the supply capacity against dryer requirements. (See heater rating plates for details.)

Fuel System Specifications and Recommendations (NG) Natural Gas

Dryer

Model #

Maximum Heat

Capacity kW

Maximum Fuel Flow

m3/h

Fuel Line Size

mm *

Heater Orifice Diameter mm **

(U = Upper, L = Lower, Heater Position)

(T = Top, M = Middle, B = Base Dryer Module)

1108/190

880

82

32

9.7

1112/270

1320

123

38

11.9

1114/320

1685

157

38

13.3

1116/370

1685

157

38

13.2

1118/400

2052

188

50

14.1

1120/460

2200

206

50

14.9

1122/511

2491

233

50

15.3

1126/601

2785

261

50

16.5

1214/2120

1700

158

38

(U)10.5 (L)8.1

1216

1993

186

50 (U)12.9

(L)8.1

1218/2125

1993

186

50

(U)12.9 (L)8.1

1220/2130

2565

239

50

(U)13.3 (L)8.1

1222

2931

273

50

(U)13.3 (L)8.1

1226/2140

3078

287

50

(U)14.1 (L)8.1

1214S/2141

2052

191

38

(U+L) 10.5

1218S/2181

2638

246

38

(U+L) 12.9

1220S/500H

3371

314

50

(U+L) 13.3

1222S/2221

4104

316

50

(U+L) 14.1

1226S/650M

4397

410

50

(U+L) 14.9

2314/3142

3445

321

50

T 13.3 B (U+L) 9.7

2318/3182

4104

316

50

T 14.1 B (U+L) 10.5

2320/3202

4837

451

80

T 14.9 B (U+L) 12.9

2322/3222

5130

478

80

T 15.3 B (U+L) 12.9

2326/3262

7183

669

80

T 16.6 B (U+L) 13.7

2420/1000H

5277

492

80

(T+B, U+L) 12.9

2426/1300M

7622

710

80

(T+B, U+L) -13.7

3414/4143

5130

478

80

T 13.3 M 13.3 B (U+L) 9.7

3418/4183

6156

574

80

T 14.1 M 14.1 B (U+L) 10.5

3420/4203

7036

656

80

T 14.9 M 14.9 B (U+L) 12.9

3422/4223

7622

710

80

T 15.3 M 15.3 B (U+L) 12.9

3426/4263

9381

874

80

T 16.6 M 16.6 B (U+L) 13.7

3620/1500H

7915

738

80

(T+M+B, U+L) 12.9

3626/2000M

11433

1065

80

(T+<M+B, U+L) 13.7