8. Vision/Dri-Tek Dryer Operation

40

PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual

Continuous Flow 5 Speed Temperature Control

1. Enable the 5 Speed option: SETUP > M/C Setup > ENABLE 5 SPD TEMPERATURE.

(See Figure 8F.)

2. Enter 5 Speed setup: 5 SPD SETUP.

(See Figure 8G.)

3. Initially use default settings.

Figure 8F

Figure 8G

4. Inner and outer limits dictate the points at which the speed increases either side of the set point.

These are set as shown in

Figure 8G

using the INC (increase) and DEC (decrease).

5 Speed
setup button

5 Speed box is
checked.