8. Vision/Dri-Tek Dryer Operation
42
PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual
Figure 8I
Figure 8J
9. Calibrate the moisture sensors, taking the average of at least three (3) samples both incoming (moist)
, SETUP > M/C Setup > CALIBRATE SENSORS > enter
offset > ACCEPT.
Example: Reading = 18.3%, Sample = 17%,
Offset = -1.3%. The moisture tester gives an average moisture of 17%, but the moisture sensor on
the dryer reads 18.3%.