14. Inspect entire dryer for loose, worn or damaged parts.

15. Check of auger flighting, metering rolls and other internal parts.

16. Check that temperature sensors within air plenum chamber are secured properly.

17. Check guards are installed and damage free.

18. Check all decals are fitted and legible.

19. Test fire the dryer several weeks ahead of the drying season. Check for possible gas leaks.

(See Page 32.)

NOTE: If on site bearing lubrication is to be performed, see lubrication instructions for ball bearing

motors. To keep motor bearings properly lubricated, and dispel any accumulation of
moisture within the windings, the fan and auger motors should be operated for 15 to 30
minute each month.