Specifications – Grain Systems PNEG-1717 User Manual

Page 20

Advertising
background image

4. Specifications

20

PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual

1200 Series Dryer Specifications

1200S Series Dryer Specifications

1214

1216

1218

1220

1222

1226

Total Holding Capacity (Bushels)

381

436

490

544

599

708

Grain Column Holding
Capacity (Bushels)

329

376

423

470

517

611

Fans

26'' 10-13 HP
36'' 10-13 HP

26'' 10-13 HP

36'' 15 HP

26'' 10-13 HP

36'' 15 HP

28'' 10-13 HP

40" 15 HP

28'' 10-13 HP

42'' 20 HP

28'' 10-13 HP

42'' 25 HP

Top Auger

8'' Dia.

5 HP

8'' Dia.

5 HP

8'' Dia.

5 HP

8'' Dia.

7-1/2 HP

8'' Dia.

7-1/2 HP

8'' Dia.

10 HP

Capacity (BPH)

3800

3800

3800

3800

3800

3800

Bottom Auger

8'' Dia.

5 HP

8'' Dia.

5 HP

8'' Dia.

5 HP

8'' Dia.

7-1/2 HP

8'' Dia.

7-1/2 HP

8'' Dia.

10 HP

Meter Roll Drive

SCR, 3/4 HP

SCR, 3/4 HP

SCR, 3/4 HP

SCR, 3/4 HP

SCR, 3/4 HP

SCR, 3/4 HP

Capacity - Maximum Rate

1

(BPH)

1960

2240

2520

2800

3080

3640

Electrical Load (Fans, Top and Bottom Augers

2

)

3 Phase, 380 Volt

50

61

61

70

75

90

1

Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate.

2

Excludes auxiliary load and unload conveyor equipment.

1214S

1218S

1220S

1222S

1226S

Total Holding Capacity (Bushels)

381

490

544

599

708

Grain Column Holding Capacity (Bushels)

329

423

470

517

611

Fans

28'' 10-13 HP (2) 36'' 10-13 HP (2)

36'' 15 HP (2)

36'' 15 HP (2)

40'' 25 HP (2)

Top Auger

8'' Dia.

5 HP

8'' Dia.

5 HP

8'' Dia.

7-1/2 HP

8'' Dia.

7-1/2 HP

8'' Dia.

10 HP

Capacity (BPH)

3800

3800

3800

3800

3800

Bottom Auger

8'' Dia.

5 HP

8'' Dia.

5 HP

8'' Dia.

7-1/2 HP

8'' Dia.

7-1/2 HP

8'' Dia.

10 HP

Meter Roll Drive

SCR, 3/4 HP

SCR, 3/4 HP

SCR, 3/4 HP

SCR, 3/4 HP

SCR, 3/4 HP

Capacity - Maximum Rate

1

(BPH)

1960

2520

2800

3080

3640

Electrical Load (Fans, Top and Bottom Augers

2

)

3 Phase, 380 Volt

50

50

80

80

115

1

Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate.

2

Excludes auxiliary load and unload conveyor equipment.

Advertising