Standard assembly without bearings – Grain Systems Custom, Utility and Bulk Tank Augers PNEG-1445 User Manual

Page 20

Advertising
background image

20 PNEG-1445 6", 8", 10" and 12" Custom Augers

4. Assembly

Assembling the Flight Extension for all 6", 8", 10" and 12"
Custom Augers

Standard Assembly without Bearings

NOTE: If the auger does not include an extension skip ahead to

Step 5 on Page 22

.

1. Begin by sliding the extension connecting band onto the main auger tube.

(See Figure 4L.)

2. Slide the flight connecting shaft into the main section of flight and bolt together with grade 8 hex bolt

and stover nut. Next slide extension flight onto connecting shaft and bolt together using proper
grade 8 bolts and stover nuts.

(See Chart below

and

Figure 4M.)

Figure 4L

Figure 4M

Flight Hardware

6"

3/8"-16 x 2" Grade 8 Hex Bolts

8"

7/16"-14 x 3" Grade 8 Hex Bolts

10"

1/2"-13 x 3-1/2" Grade 8 Hex Bolts

12"

5/8"-11 x 4" Grade 8 Hex Bolts

(

See Chart above

for bolt sizes.)

Advertising