Installing the intake guard (continued) – Grain Systems Custom, Utility and Bulk Tank Augers PNEG-1445 User Manual

Page 26

Advertising
background image

26 PNEG-1445 6", 8", 10" and 12" Custom Augers

4. Assembly

Installing the Intake Guard (Continued)

2. With the intake shaft inserted in the bushing make sure to leave approximately 1/2" of clearance

between the end of the flight and the face of the bushing.

(See Figure 4W.)

Figure 4W

3. Attach the intake guard to the tube using the proper hex bolts and nylock nuts through the half

bands that are welded to the intake guard.

(See Chart below

and

Figure 4X.)

Figure 4X

Intake Guard Bolts

6"

5/16"-18 x 1-3/4" Grade 5 Hex Bolt

8"

5/16"-18 x 1-3/4" Grade 5 Hex Bolt

10"

3/8"-16 x 1-1/2" Grade 5 Hex Bolt

(

See Chart above

for bolt sizes.)

Advertising