Ad to, Standard assembly without bearings (continued), Assemblies with internal bearings – Grain Systems Custom, Utility and Bulk Tank Augers PNEG-1445 User Manual

Page 22

Advertising
background image

22 PNEG-1445 6", 8", 10" and 12" Custom Augers

4. Assembly

Standard Assembly without Bearings (Continued)

5. Insert the intake shaft into the flight and connect with proper grade 8 bolt and stover nut.

(See Chart below

and

Figure 4P.)

Figure 4P

Assemblies with Internal Bearings

1. Slide connecting band onto main auger tube, and attach connecting stub to main auger flight using

the assigned hardware.

(See Chart below

and

Figure 4Q on Page 23.)

Flight Hardware

6"

3/8"-16 x 2" Grade 8 Hex Bolts

8"

7/16"-14 x 3" Grade 8 Hex Bolts

10"

1/2"-13 x 3-1/2" Grade 8 Hex Bolts

12"

5/8"-11 x 4" Grade 8 Hex Bolts

Flight Hardware

6"

3/8"-16 x 2" Grade 8 Hex Bolts

8"

7/16"-14 x 3" Grade 8 Hex Bolts

10"

1/2"-13 x 3-1/2" Grade 8 Hex Bolts

12"

5/8"-11 x 4" Grade 8 Hex Bolts

(

See Chart above

for bolt sizes.)