Chapter 4 - configuration management, 6 usm user – Asus GigaX1024iPlus User Manual

Page 41

Advertising
background image

32

Chapter 4 - Configuration Management

ASUS GigaX 1024i+

matches the Oid in the SNMPv3 message.

View Subtree: Enter the View Subtree that the View belongs to. The

Subtree is the Oid to match the Oid in the SNMPv3 message. The match

is good when the subtree is shorter than the Oid in the SNMPv3 message.

View Mask: Enter the View Mask that the View belongs to. Each bit in

the mask represents the digit between the dots of View Subtree from left

side. Bit ‘0’ means ‘nothing’.
Click <

Add> to create a new VACM View entry. To remove an existing

entry, select the view and click <

Remove>. To update an existing entry,

select the view and click <

Modify>. Click <OK> to save the changes on

this page. Click <

Reload> to refresh the settings. To permanently save the

new configuration, go to the

Save Configuration page, then click <Save>.

4.4.6 USM User

USM (User-based Security Model)

User is used to configure the

information of SNMPV3 USM User.
The USM User page has the

following parameters:

Engine Id: Enter the Engine Id that

matches the ID in the Manager.

Name: Enter Name combined with Engine ID that should match the

Name and Engine ID in the Manager.

Auth Protocol: Enter the Auth Protocol that Engine ID and Name belong

to. Only NoAuth, MD5, SHA1 can be chosen. If the NoAuth is chosen,

there is no need to enter the password.

Auth Password: Enter the password that the Auth Protocol belongs to.

The password needs at least 8 characters or digits.

Priv Protocol: Enter the Priv Protocol that Engine ID and Name belong

to. Only NoPriv ,DES can be chosen. If the NoPriv is chosen, there is no

need to enter password.

Priv Password: Enter the password that the Priv Protocol belongs to.

The password needs at least 8 characters or digits.
Click <

Add> to create a new USM User entry. To remove an existing

entry, select the entry and click <

Remove>. To update an existing entry,

select the entry and click <

Modify>. Click <OK> to save the changes on

this page. Click <

Reload> to refresh the settings. To permanently save the

new configuration, go to the

Save Configuration page, then click <Save>.

Figure 34. USM User