Repairs, Spare parts, spare pumps – Xylem IM157 Model MPVN User Manual

Page 10

Advertising
background image

10

29. Relief fittings insufficient

• clean balance in impeller

• replace worn parts (impeller, split rings)

• adjust in line with the system pressure/intake

pressure given on ordering

30. System-related vibrations (resonance)

• seek assistance

31. Flow indicator wrong

• check flowmeter

• get rid of blockages

• put flowmeter in suitable place (no flow distortion

or burbling)

8. REPAIRS

Repairs to the pump or pump system may only

be carried out by authorized skilled personnel

or by the distributor’s specialist staff.

Trained Customer Service engineers are available to

assist with installation and repair work on request. When

removing the pump, you must comply with Point 1.4

“Safety Instructions”, Point 3.1 “Transport, Handling”

and Point 4.8 “Dismantling”.

9. SPARE PARTS, SPARE PUMPS

9.1 Spare Parts

Spare parts should be selected to last for two-years

continuous operation. If no other guidelines are

applicable, we recommend that you stock the number of

parts listed below.

Number of Pumps (including stand-by pumps)

2

3

4

5 6/7 8/9 10+

Spare Part

Number of Spare Parts

Impeller

i

i

i

2i

2i

3i 30%

Diffuser

i/2

i/2 i/2

i

i

3i/2 15%

Shaft with key and shaft screws/nuts

1

1

2

2

2

3 30%

Bearing (roller bearing)

1

1

2

2

2

3 30%

Shaft

sleeve

2 2 2 3 3 4

50%

Joints for Pump Casing – sets

4

6

8

8

9

12 150%

Other joints†– sets

4

6

8

8

9

10 100%

Mechanical

seal

2 3 4 5 6 7

90%

i = no. of stages

ATTENTION: TO ENSURE OPTIMUM

AVAILABILITY, WE RECOMMEND

THAT SUITABLE QUANTITIES OF

SPARE PARTS ARE HELD IN STOCK,

ESPECIALLY IF THESE ARE MADE

FROM SPECIAL MATERIALS AND IN

THE CASE OF MECHANICAL SEALS,

BECAUSE OF THE LONGER

DELIVERY TIMES.

Ordering Spare Parts

When ordering spare parts, please supply the following

information:
Pump Type:
Pump Order No.
Part Designation in sectional drawing
All the information is given in the Data Sheet and the

relevant sectional drawing.
9.2 Stand-By Pumps

It is essential that a sufficient number of stand-

by pumps are kept ready for use in plants where

failure of a pump could endanger human life or

cause damage to property or high costs. Regular

checks should be carried out to ensure that such pumps are

always ready for use (see Point 6.2).

Advertising