5

Lubrication of Roller Bearings

Standard: grease lubrication with grease nipples.
Grease lubricants to be of Lithium Base Grade 2.
The bearings are already filled with grease and are thus

ready for use.
Bearing Types (roller bearings)

Pump Size

Grease Lubricated

Bearing

MPVN 40.2 / MPVN 40.3

B306-C3

MPVN 65.2 / MPVN 65.2

B307-C3

MPVN 100.1 / MPVN 100.2

2 x 7308 (X-arrangement)

MPVN 125.1 / MPVN 125.2

2 x 7310 (X-arrangement)

Interval of re-lubrication / grease quantity

Grease Interval of re-lubrication in operating hrs

Pump Size

Qty. 3550 2950 2200 1750 1450

[oz.]
MPVN 40.2 / MPVN 40.3

0.41

3800

4300 5500

6000

6500

MPVN 65.1 / MPVN 65.2

0.53

3500

4000 5000

5500

6000

MPVN 100.1 / MPVN 100.2 0.78

3300

3800 4500

5000

5500

MPVN 125.1 / MPVN 125.2 1.12

2500

3300 4300

4800

5000

3. TRANSPORT, HANDLING, STORAGE

3.1 Transport, Handling

• Check the pump/pump unit immediately

upon delivery/receipt of shipment for

damage or missing parts.

• The pump/pump unit must be transported

carefully and by competent personnel.

Avoid serious impacts.

• Keep the pump/pump unit in the same

position in which it was supplied from the

factory. Take note of the instructions on the

packaging.

• The intake and discharge side of the pump

must be closed with plugs during transport

and storage.

ATTENTION: DISPOSE OF ALL

PACKING MATERIALS IN

ACCORDANCE WITH LOCAL

REGULATIONS.
• Lifting devices (e.g. fork-lift truck, crane, crane device,

pulleys, sling ropes, etc.) must be sufficiently strong.

• The pump/pump unit may only be lifted by solid

points such as the casing, flanges or frame. The

illustration above shows the correct method of carrying

by crane.

Do not stand underneath suspended loads; take

note of the general regulations on prevention of

accidents.

The pump/pump unit must be secured against tipping

over and slipping until it has been fixed in its final

location.
3.2 Storage

Pump or pump units that are stored for a long time

before use must be protected against moisture,

vibrations and dirt (e.g. by wrapping in oil paper or

plastic sheeting). Pumps must basically be stored in a

place where they are protected from the weather, e.g.

under cover. During this time, all suction and discharge

branches and all other intakes and outlets must be closed

with dummy flanges or plugs.

Preservation

On storing the pump longer than 3 months (depends on

order): Special preservation has been used for shipment

prep. The product used for that must be removed from

the unit before the first normal operation.

4. INSTALLATION, OPERATION

4.1 Assembly and Connection of Pump

MPVN type pumps must be bolted to a fixed subframe

(e.g. concrete foundation, steel plate, steel beam, etc.).

The subframe must withstand all loads that arise during

operation. The size of the subframe and the location and

size of the recesses for the foundation anchors are given

in the dimension drawing, which is binding.
ATTENTION: SUFFICIENT SPACE MUST BE

PROVIDED FOR MAINTENANCE

AND REPAIR WORK, ESPECIALLY

FOR REPLACING THE DRIVE

MOTOR OR THE COMPLETE

PUMP UNIT. THE MOTOR FAN

MUST BE ABLE TO TAKE IN

ENOUGH COOL AIR, AND THE

INTAKE GRILLE MUST THEREFORE

BE AT LEAST 10 CM AWAY FROM

ANY WALL, ETC.

To prevent vibrations being transmitted to adjoining

components, the foundation should be laid on a suitable

insulating base (panels providing insulation against

structure-borne sound or vibration panels).
ATTENTION: THE SIZE OF THESE INSULATING

PANELS WILL VARY, DEPENDING

ON CIRCUMSTANCES, AND

SHOULD THEREFORE BE

DETERMINED BY AN

EXPERIENCED SPECIALIST.

Concrete foundations must be completely set and the

surfaces must be smooth before the pump unit is mounted.

Put pump unit onto the foundation and, if necessary, level

vertically with the help of thin sheet-metal panels (with spirit

level). Tighten foundation anchor evenly and firmly.

The alignment must be carried out with the utmost

care and attention, so that the unit will operate

without failure. If you do not pay attention to this

hint you will lose your warranty!

4.2 Installation and Alignment of Coupling

Make sure that nobody can start the motor

when work is being carried out on the

coupling. In accordance with the Accident

Prevention Regulations, the pump unit may

only be operated when the coupling guard is mounted.
• Before starting installation, carefully clean shaft ends

and coupling components.

• Pull coupling hub onto motor shaft end. The coupling

may be heated beforehand in an oil bath to approx.

100°C. The motor hub will need to be mounted flush

to the motor shaft.

• The motor coupling hub will have an interference fit

and the pump coupling hub will have a clearance fit.

The clearance allows the pump hub to be adjusted on

the pump shaft. Keep pump hub loose for adjusting the

elastomer element.

• Place half of the coupling elastomer element around

the hubs and secure with self-locking capscrews.