Xylem IMVS R01 Model VS Vertical Industrial Turbine Pumps User Manual

Page 5

Advertising
background image

5

considered in storage when it has been delivered to the

job site and is awaiting installation. If a pump has been

installed, but is not in regular operation, such as seasonal

shutdown or an extended period of time, it is suggested

that the pump be operated for at least 15 minutes every

two weeks if possible.

2–3 RECOMMENDED STORAGE PROCEDURES

1. Controlled storage facilities should be maintained at

an even temperature 10º F (5.6°C) or more above the

dew point with relative humidity less than 50% and

little or no dust. (If these requirements cannot be met

the pump is to be considered in uncontrolled storage.)

2. For uncontrolled storage periods of six months or less,

the pump is to be inspected periodically to insure that

all preservatives are intact.

3. All pipe threads and flanged pipe covers are to be

sealed with tape.

4. The pump must not be stored closer than six inches to

the ground.

2–4 PREPARATIONS FOR UNCONTROLLED

LONG TERM STORAGE

Storage periods over six months require the preceding

uncontrolled storage procedure plus the following:
1. Inspect the assembly and recoat periodically to prevent

corrosion.

2. Place ten pounds of moisture absorbing desiccant or

five pounds of vapor phase inhibitor crystals near the

center of the pump. If the pump is assembled, place an

additional one pound in the discharge nozzle securely

fastened to the discharge flange.

3. Install a moisture indicator near the perimeter of the

pump. Cover the pump with 6 mils (0.15 mm) mini-

mum thickness black polyethylene or equal and seal

it with tape. Provide a small ventilation hole approxi-

mately ½ inch diameter.

4. Provide a roof or a shed shelter to protect from direct

exposure to the elements.

SECTION 3 — GENERAL DESCRIPTION

3–1 GENERAL DESCRIPTION

Goulds Water Technology model VS pump is a submers-

ible turbine pump designed for maximum dependability.

See Figure 1 for typical VS pump.

3–2 DRIVERS

Goulds Water Technology furnishes only internationally

recognized motors designed for continuous operation

under any thrust which may develop throughout the

performance curve. Impeller adjustment and type of

coupling, splined or clamped, is dependent on the

specific motor being used.

3–3 DISCHARGE

The discharge bowl provides an NPT or BSP thread for

connecting to the well head or the first section of column

pipe.

Figure 1 – Typical Submersible Pump Installation

3–4 BOWL ASSEMBLY

The bowls are generally flanged construction for accurate

alignment and ease of assembly and disassembly. Impel-

lers may be enclosed or open type. Impeller position is

set at factory. No field adjustment is required.