6.1.2 Mechanical mounting

Variant for HV1.1

1. Remove the motor fan cover from

your 3-phase motor by removing the

mounting screws.


2. Put the mounting and distance ring

(1) between the fan cover and the
Hydrovar and fix them together with

the screw (3) by using the included
washer(2).



3. Use the fan cover screws to mount

the fan cover/Hydrovar combination
to the motor










Attention:

Don’t forget the washer between the screw and the motor fan cover!