15 Possible Error messages

15.1 Low Water

XXX

Error Water

Remedy:

Check incoming pressure

If incoming pressure is normal the unit restarts itself. If there is no external low water
protection (e.g. circulating systems), you have to bridge terminals X2/6 and X2/7.

15.2 Overheating – Motor

XXX

Error-Mot-Temp

Possible causes: insufficient cooling,

ambient temperature is too high or motor

overloaded. After the cause has been remedied, the malfunction has to be reset by
cutting off the power supply for >30 seconds.

15.3 Overvoltage

XXX

Error-Overvolt

Possible cause: Check mains supply, supply
voltage too high, peak voltage owing to

switch heavy loads on the network, or RAMP 2 is to fast! Find the cause and take
countermeasures (e.g. network filter, RC-elements). Disconnect the power supply for
> 30 seconds (acknowledgement).

15.4 Undervoltage

XXX

Error-Undervolt

Possible cause: Check mains supply, faulty
fuse or phase Unsymmetry.

Disconnect the power supply for > 30 seconds (acknowledgement).

15.5 Overload

XXX

Error Overload

Possible causes: false data settings or the
pump is working at a capacity significantly in

excess of its performance data.
Ramp 1 to fast: (see chapter 13.6.3)

Max. frequency to high: (see chapter 13.5.1)
Boost to low: (see chapter 13.5.3)
Disconnect the power supply for > 30 seconds (acknowledgement).