4.
In the Sync to Matrix panel, select
Enabled
from the
Enabled/Disabled radio
buttons
(see figure 86).
4
5
6
7
8
9
EDID
Sync-To-Matrix
Advanced Settings
Figure 86.
Advanced Settings Page — Sync-To-Matrix
5.
Use the
Video Out
field to enter the number of the matrix switcher video output port
connected to the SME 100.
6.
Use the
IP Address
field to enter the IP address of the matrix switcher connected to
the SME 100.
7.
Use the
Telnet Port
field to enter the Telnet port of the matrix switcher connected to
the SME 100. The default is
23
.
8.
If a password is needed to access the matrix switcher connected to the SME 100, use
the
Password
(if req.)
field to enter the password.
9.
Click the
Submit
button to save the configuration settings and sync the SME 100 to the
matrix switcher.
NOTES:
•
If the SME 100 successfully syncs with the matrix switcher, the
Status
field will
display
Connected
.
•
If the
Status
field continues to display
Not Connected
, check the settings of
the matrix switcher and the SME 100 and try resyncing the devices.
SME 100 • Web-based Configuration Page