SME 100 Reset Mode Summary

Mode Activation

Result

Purpose and Notes

Factory Firmwar

e

1

Hold in the recessed Reset
button while applying power
to the unit.

The SME 100 reverts to the factory
default firmware for a single power
cycle.
Booting to this mode twice in a row
deletes all user files; settings (such as
drivers, adjustments, and IP settings)
are set to factory default.

Use mode 1 to revert to
the factory default firmware
for a single power cycle if
incompatibility issues arise
with user-loaded firmware.

Reset All IP Settings

4

Hold in the Reset button for
about 6 seconds until the
Power LED blinks twice (once
at 3 seconds, again at 6
seconds). Then, release and
press Reset again within
1 second*.

Mode 4:

•

Enables ARP capability.

•

Sets the IP address back to
factory default (192.168.254.254).

•

Sets the subnet mask address
back to the factory default
(255.255.0.0).

•

Sets the gateway IP address to
the factory default (0.0.0.0).

•

Sets port mapping back to factory
default.

•

Turns DHCP off.

•

The Reset LED on the rear panel
of the unit flashes four times in
succession.

Mode 4 is used to set
IP address information using
ARP and the MAC address.

A "Resetting IP Settings"
message appears on the
LCD display.

Reset to Factory Defaults

5

Hold in the Reset button for
about 9 seconds until the
Power LED blinks three times
(once at 3 seconds, again
at 6 seconds, again at 9
seconds). Then, release and
press Reset again within
1 second*.

Mode 5:
Performs a complete reset to factory
defaults (except the firmware).

•

Does everything mode 4 does.

•

Clears port configurations.

•

Resets all IP options.

•

Clears all user settings.

•

Clears all files from the unit.

•

The Reset LED on the rear panel
of the unit flashes four times in
succession.

Mode 5 is useful when wanting
to start over with configuration
and uploading, and also to
replace events.

"Resetting SME 100" appears
on the LCD display.

NOTE: * = For modes 4 and 5, nothing happens if the momentary press does not occur within 1 second.