Extron Electronics SME 100 User Guide User Manual

Page 138

Advertising
background image

X13$

=

Daylight savings time

0 = Off (ignore)
1 = U.S.A.
2 = Europe
3 = Brazil

X14!

=

Check password

The actual password is not shown.
If a password is set, four asterisks (****) are returned.
If a password is not set, nothing is returned.

X14(

=

Default name: shows the default name of the unit using the model name and
the last three pairs of the MAC address.
Example:

SME-100-HD/SD-00-02-3D

X15@

=

Connection security level

NOTES:

•

The response is returned as two digits.

•

A leading zero is used for values lower than 10.

00 = Anonymous
01-10 = Extended security levels (1 through 10)
11 = User (viewer)
12 = Administrator

X16(

=

IP connection timeout: 1 through 65000 (default = 30 = 300 seconds)

NOTES:

•

Applicable to Ethernet connections only.

•

The selected number multiplied by 10 determines the number of
seconds required for a connection timeout.

•

If no data is received during the connection timeout period, the
Ethernet connection is closed.

•

The response is returned as five digits with leading zeros.

•

Connection timeouts can be set on the RS-232 port when using
the global timeout commands only. Using the current port timeout
commands returns the

E13

error.

X18!

=

Text (up to 64 characters)

SME 100 • Remote Communication and Control

132