Basic wave command, Bswv – B&K Precision 4052-4055 - Programming Manual User Manual
Page 11
7
1.5. Basic Wave Command
DESCRIPTION Set or get basic wave parameters.
COMMAND SYNTAX
<channel>:BaSicWaVe <parameter>
<channel>:={C1, C2}
<parameter>:= {a parameter from the table below}
Parameters
Value
Description
WVTP
<type>
Type of wave
FRQ
<frequency>
Value of frequency. This parameter
cannot be set for noise wave.
AMP
<amplifier>
Value of amplifier. This parameter ca
nnot be set for noise wave.
OFST
<offset>
Value of offset. This parameter cann
ot be set for noise wave.
SYM
<symmetry>
Value of symmetry. This parameter is for
ramp wave only.
DUTY
<duty>
Value of duty cycle.
Only Pulse and Duty can set this
parameter.
PHSE
<phase>
Value of phase. This parameter cann
ot be set for noise wave.
VAR
<variance>
Value of noise wave Variance. This
parameter can be set for noise wave
only.
MEAN
<mean>
Value of noise wave mean. This
parameter can be set for noise wave
only.
DLY
<delay>
Value of delay. This parameter can be set
for pulse wave only.
Note: if the command doesn’t set basic wave type, the parameter will set parameters to current
device wave type by default.
where:
<type>:={SINE, SQUARE, RAMP, PULSE, NOISE, ARB ,DC}
<frequency>:= { Default unit is "HZ". Minimum value is 1xe-6 HZ,
maximal value depends on the version.}
<amplifier>:= {Default unit is "V". Channel one minimum value 0.004V,