B&K Precision 4052-4055 - Programming Manual User Manual
Page 21

17
<offset>:={ Default unit is "V". the maximal value depends on the
version.}
<duty>:={ If wave type is Square, range is from 20% to 80%
If wave type is pulse, range is from 0.1% to 99.9%}
<symmetry>:={ 0% to 100%}
<carr delay>:= {Maximal is Pulse Period, minimum valve is 0. Unit
is S.}
<variance>:={0.4mv to 666.6mv}
<mean>:={ the maximal value depends on the variance}
QUERY SYNTAX
<channel>:BursTWaVe? <parameter>
<parameter>:=<period>……
RESPONSE FORMAT
<channel>:BursTWaVe <type>|<state>|<period>……
EXAMPLE 1 Set channel one burst wave period to 1S.
C1:BTWV PRD, 1S
EXAMPLE 2
Set channel one burst wave delay to 0S
C1:BTWV DLAY, 0S
EXAMPLE 3
Reads channel two burst wave parameters that STATE is ON.
C2: BTWV?
Return:
C2:BTWV
STATE,ON,PRD,0.01S,STPS,0,TRSR,INT,TRMD,OFF,TIME,1,DLAY,2.4e-07S,,
GATE_NCYC,NCYC,CARR,WVTP,SINE,FRQ,1000HZ,AMP,4V,OFST,0V,PHSE,0
EXAMPLE 4
Reads channel two modulate wave parameters that STATE is OFF.
C2: BTWV?
Return:
C2: BTWV STATE,OFF