22


QUERY SYNTAX

SCreen_SaVe?


RESPONSE FORMAT

SCreen_SaVe <parameter>


EXAMPLE 1

Set screen save time 5 minutes.

SCSV 5

1.16. Clock Source Command

DESCRIPTION

Set or get signal oscillator resource .


COMMAND SYNTAX ROSCillator <parameter>

<parameter>:= {INT, EXT }


QUERY SYNTAX

ROSCillator?


RESPONSE FORMAT ROSC <parameter>

EXAMPLE 1

Uses system clock source.

ROSC INT

1.17. Frequency Counter

DESCRIPTION

Set or get frequency counter.


COMMAND SYNTAX FreqCouNTer {TRG,<value>,MODE, <value>,HFR,<value>,DEF ,<value>}

<value> = {see below table.}


QUERY SYNTAX

FreqCouNTer? {FRQ, DUTY, TRG, PW, NW, MODE, HFR}


RESPONSE FORMAT

FreqCouNTer <parameter>



Parameters

Value

Description

STATE

<state>

Turn on or off frequency counter

FRQ

<frequency>

Input signal frequency.

DUTY

<duty>

Input signal duty.