Burst wave command – B&K Precision 4052-4055 - Programming Manual User Manual

Page 19

Advertising
background image

15

EXAMPLE 4

Reads channel two modulate wave parameters that STATE is OFF.

C2:SWWV?

Return:
C2:SWWV STATE,OFF



1.8. Burst Wave Command

DESCRIPTION

Set or get burst wave parameters.


COMMAND SYNTAX

<channel>:BursTWaVe <parameter>

<channel>:={C1, C2}

<parameter>:= {a parameter from the table below.}


Parameters

Value

Description

STATE

<state>

Enable or disable burst wave. Note if
you want to set or read burst wave
parameters you must first enable burst
mode.

PRD

<period>

When carrier wave is NOISE wave, this
cannot be set. When GATE is selected,
you cannot set this. This can be set
only when trig source is IN (internal).

STPS

<start phase> When carrier wave is NOISE or PULSE

wave, you can’t set it.

GATE_NCYC

<gate ncycle> When carrier wave is NOISE, you can’t

set it.

TRSR

<trigger>

When carrier wave is NOISE wave, you
can’t set it. When NCYC was chosen
you can set it.

DLAY

<delay>

When carrier wave is NOISE wave, you
can’t set it. When NCYC was chosen
you can’t set it.

PLRT

<polarity>

When GATE was chosen you can set it.
When carrier wave is NOISE, it is the
only parameter.

TRMD

<trig mode>

When carrier wave is NOISE wave, you
can’t set it. When NCYC was chosen
you can set it. When TRSR is set to
EXT, you can’t set is.

Advertising