MoTeC M880 User Manual

Page 48

Advertising
background image

46

Initial Starting Procedure

SYNC Error

The SYNC signal has occurred before expected.

Possible causes :

A bad SYNC signal has caused extra SYNC pulses - check voltage
levels with a scope.

A bad REF signal has caused missing REF pulses - check voltage
levels with a scope.

Bad REF / SYNC alignment.

Incorrect Setup

No SYNC

Two or more consecutive SYNC pulses are missing.

Possible causes :

No SYNC signal - check the wiring and SYNC sensor voltage levels
with a scope.

A bad REF signal has caused many extra pulses - check voltage
levels with a scope.

Incorrect Setup

Multiple REF / SYNC Errors

Multiple REF / SYNC errors may occur, often the first error to occur is
the correct error.

Multiple errors may also occur due to incorrect Setup.