Appendix B: Sensor Supplies

Maximum Current

5V ENG Sensor Supply: 0.20 Amps Max

5V AUX Sensor Supply: 0.15 Amps Max

8V ENG Sensor Supply: 0.30 Amps Max

8V AUX Sensor Supply: 0.30 Amps Max

Accuracy / Temp Drift

5V ENG Sensor Supply:

± 0.5% max at 25°C + 100ppm/°C max

5V AUX Sensor Supply:

± 0.5% max at 25°C + 100ppm/°C max

8V ENG Sensor Supply:

± 5% max over entire temperature range

8V AUX Sensor Supply:

± 5% max over entire temperature range

Protection

Short to ground

Short to battery

Thermal overload