80 Appendices

Lambda Inputs

Wideband

Sensor Type: NTK or Bosch LSU

Measurement Range : 0.70 to 32.0 Lambda

Narrow Band

The LA1S and LA2S inputs may be used to measure the voltage of
normal narrow band oxygen sensors.

Note: If closed loop control is to be used then an external 33k ohm bias
resistor from the input to 0V is required to bias the input to
stoichiometric (0.45V) while the sensor is cold.

Voltage Input

The LA1S and LA2S inputs may be used as ordinary voltage inputs.

Specifications are the same as the Analog Voltage inputs except the
inputs include a 220k ohm resistor to 5V.

Digital Inputs

Suitable for : Switch to 0V, Logic signal & open collector device (eg Hall
Switch)

Pullup Resistor : 4700 ohms to 5V

Voltage Range : 0 to 15V

Positive Trigger Threshold : 3.5 V max

Negative Threshold : 1.0 V min

Hysteresis : 0.5 V Min

Filter Time Constant : 22usec

Trigger Edge: Programmable

Measurement Methods: Switched, Speed / Frequency, Period, Pulse Width