For best calibration the indicator should be within or close to the centre
rectangle, this ensures that the ECU tuning is determined mainly by the
site being adjusted and not by the adjacent sites.

Up / Down Adjustment

Up or Down adjustments may be made to the selected table value using the
PgUp and PgDn keys.

Fast adjustments may be made by holding the Ctrl key down while
pressing the PgUp or PgDn keys. This will increment the value by ten
times the normal amount.

If the PgUp or PgDn keys are held down the value will continue to change
until the key is released.

Locking in the New Value

When the desired adjustment has been made the new value must be locked
in (“Set”) by pressing the Enter key, this stores the new adjustment in the
ECUs programmable memory.

If the cursor is moved before pressing the Enter key the value will revert to
its previous unadjusted value.

Direct Entry

The table values may also be entered directly using the number keys followed
by the Enter key.

Maths Operations

Mathematical operations may be performed on the currently selected value or
the WHOLE table or a BLOCK within a table.

To perform a maths function enter the value followed by an operation key (+, -
, *, / ), for example 2.5+ will add 2.5 to the current table value.

To apply the maths operation to the whole table type a T before pressing the
operation key, for example: 2.5T+ will add 2.5 to the whole table.

Block Operations

To mark a block hold down the shift key while pressing the arrow keys then
perform a maths operation.