7 unbalance correction, 1 iron rims – CEMB USA ER100-i (B) User Manual
Page 25

25
Use and Maintenance Manual Rev. 12-2012
ENGLISH
Displays the information screen
Selects unbalance display in g/oz
Traceability management
Enables/disables wheel in correction position
Unbalance split (not selectable for correction with
clip-on weights)
Displays the second set of buttons
Lift reset with wheel stopped / STOP during spin
WEIGHT APPLICATION POSITION
Correction type
Inside
Outside
Clip-on weight at 12 o’clock
Clip-on weight at 12 o’clock
Clip-on weight at 12 o’clock
Adhesive weight at 12 o’clock
Adhesive weight at the point indicated
by the internal laser
Clip-on weight at 12 o’clock
Adhesive weight at the point indicated
by the internal laser
Adhesive weight at 12 o’clock
Adhesive weight at the point indicated by the internal laser
Use of the wheel balancing machine
6.7
UNBALANCE CORRECTION
After an unbalance measurement spin, the weight shadow indicates the correct application point.
6.7.1 Iron rims