Use and Maintenance Manual Rev. 12-2012

ENGLISH

Confirms loading of the factory settings

Goes back to the reserved setup screen

8.4

MACHINE CALIBRATION

Reserved for Technical Service

Saves the calibration values

Confirm

Goes back to the setup screen

Goes back to the main screen

Reserved Setup

1. Select a commercial wheel or sample wheel based on the type of wheel you intend to use for calibration and press

the

button.

2. Mount the wheel selected, close the guard and press the

button.

3. Set the value of the sample weight used for the calibration.

4. Open the guard, apply the sample weight on the outside of the wheel, close the guard and press the

button.

5. Open the guard, apply the sample weight on the inside of the wheel in the same position as it was applied on the

outside, close the guard and press the

button.

6. Move the sample weight to 12 o’clock and press the

button.

7. Press the calibration save button

.

8. Press the

button to go back to the measurement screen.