English – CEMB USA ER100-i (B) User Manual

Page 81

Advertising
background image

81

Use and Maintenance Manual Rev. 12-2012

ENGLISH

Diagnostics

Err. 20

Message management error (incorrect

or no translations) (only for releases

prior to M3343).

1. Change the language, selectable in Setup.

2. Contact Technical Service to find out if the on-screen messages can

be updated in the various languages.

Err.21

Err. 22

Date and time setting error

1.

Repeat the date and time setting function.

2.

Check that you have set numbers compatible with the date and time

format.

Err. 31/

Err. 32/

Err. 33/

Err. 34/

Err. 39/

Err. 42

Firmware upgrade management error.

1.

Check that you have loaded a file with extension BI5.

2.

Repeat the firmware upgrade function.

Err.50

Error in eccentricity measurement using

the external laser

1. Check that you have correctly mounted the wheel or rim.

2. Check that during measurement (wheel at full speed), the red light

of the external laser is aimed at the tyre or the rim.

3. Open the spindle, close the spindle and repeat the eccentricity

measurement function.

Err.51

Error in eccentricity measurement using

the internal laser

1. Check that you have correctly mounted the wheel or rim.

2. Check that during measurement (wheel at full speed), the red light

of the internal laser is aimed at the tyre or the rim.

3. Open the spindle, close the spindle and repeat the eccentricity

measurement function.

Err.60

Error: the spindle is not closing.

1. Use the self-diagnostics function to check proper functioning of the

spindle.

Err.61

Error: the spindle is not opening

1. Check the pneumatic system air pressure.

2. Check the spindle opening/closing control microswitch.

3. Check that there are no mechanical obstructions hindering spindle

opening/closing.

Err.70

Error. Lift down and does not ascend.

1. Use the self-diagnostics function to check proper functioning of the lift.

2. Check proper functioning of the microswitch that detects the lift in

rest position.

3. Check the pneumatic system air pressure.

Err.71

Error. Lift up and does not descend.

1. Use the self-diagnostics function to check proper functioning of the lift.

2. Check proper functioning of the microswitch that detects the lift in

rest position.

3. Check that there are no mechanical obstructions hindering lift descent.

Err.72

Error. Lift up during unbalance,

eccentricity and taper measurement

1. Lower the lift before starting any measuring cycle

Err.75

Error in the taper calibration function.

1. Use the self-diagnostics function to check proper functioning of the

external laser.

2. Check that the external laser light spot is aligned with the spindle.

3. Check that you have correctly fitted the calibration tool.

4. Repeat the taper calibration function.

Err.100

Error in sending parameters from the PC

to the acquisition board.

1. Reset the wheel balancing machine.

If the problem persists:

1. Check the connection cables between the PC and the acquisition board.

2. Replace the acquisition board.

3. Replace the PC.

Err. 121

Err. 123/124

Err. 125/126

Err. 127/128

Err. 129/130

Internal laser motor control error.

1. Reset the wheel balancing machine.

If the problem persists:

1. Check compatibility between the software and the firmware.

2. Reinstall the software and the firmware.

Err. 141

Err. 143/144

Err. 145/146

Err. 147/148

Err. 149/150

External laser motor control error.

1. Reset the wheel balancing machine.

If the problem persists:

1. Check compatibility between the software and the firmware.

2. Reinstall the software and the firmware.

Err. 122/131

Err. 142/151

The internal/external laser does not

reach the position requested.

1. Check that there are no mechanical obstructions hindering

laser movement.

2. Check functioning of the stepper motor belt.

3. Check the stepper motor power supply.

4. Check the stepper motor connection cables.

5. Where provided, check the encoder on the stepper motor slide.

Err. 127/147

Internal/external laser stepper motor

turning in reverse direction.

1. Check the stepper motor connection.