Pumps: installation and operating instructions, Warning – AAON LC-054 User Manual

Page 28

Advertising
background image

28

Dimensions & Weights

Product

Number Size

A

B

C

D

E

F

Cv

Weight

Lbs Kg.

431

1”

6”

4”

2-1/2”

**

1/2” NPT 1/8” NPT

31.4

4

1.8

432

1-1/4”

6”

4”

2-1/2”

**

1/2” NPT 1/8” NPT

53.5

4

1.8

433

1-1/2”

8”

6”

4”

3/4” NPT

1/2” NPT 1/8” NPT

61

7

3.2

434

2”

8”

6”

4”

3/4” NPT

1/2” NPT 1/8” NPT 106.6

7

3.2

435

2-1/2”

10”

8”

5-1/2”

1” NPT

1/2” NPT 1/8” NPT

140

15

6.8

436

3”

10”

8”

5-1/2” 1-1/4” NPT 1/2” NPT 1/8” NPT

276

14

6.4

437*

4”

16-5/16” 11-5/8” 7-1/8” 1-1/2” NPT 1/2” NPT 1/8” NPT

600

52

23.6

*This size has 125 lb. flanged ends.

**No conventional plain steel expansion tank tapping.

Pumps: Installation and Operating

Instructions

Introduction

This document contains specific information

regarding the safe installation, operating and

maintenance of Vertical In-Line pumps and

should be read and understood by installing,

operating and maintenance personnel. The

equipment supplied has been designed and

constructed to be safe and without risk to

health and safety when properly installed,

operated and maintained. The instructions

following must be strictly adhered to. If

clarification is needed on any point please

contact Armstrong quoting the equipment

serial number.

Where under normal operating conditions

the limit of 68°C/155°F (Restricted Zone)

for normal touch, or 80°C/176°F

(Unrestricted Zone) for unintentional touch,

Improper installation, adjustment,

alteration, service or maintenance

can cause property damage,

personal injury or loss of life.

Installation and service must be

performed by a trained, qualified

installer.

WARNING

Installation of this equipment should

not take place unless this document

has been read and understood.

WARNING

Advertising