Unlocking:

1. Open the interconnecting valve on the

seal flush line to pressurize the serviced

pump and vent air through bleeder valve on

series 4302.

Close these valves once the pressure is

equalized and air removed.

2. Loosen set screw (11) and lower locking

handle (3) to the horizontal position, secure

with set screw (11).

3. Rotate valve to center position so that the

center pin of the locking arm (4) locates in

the recess on the locking handle (3).

4. Loosen set screw (11) and raise locking

arm (3) to the vertical position, locking the

center pin in the locking arm recess, secure

with set screw (11).

Suction Valve

Manual Operation:

The suction side valve is designed for use as

a manually operated isolation valve. This

valve is not designed to automatically pivot

as the discharge flappers do.

Locking:

1. Loosen suction side set screw (11) to

release the locking handle (3).

2. Rotate the suction side locking handle (3)

so that the handle points towards the pump

to be serviced and secure in the horizontal

position, using set screw (11). This releases

the suction locking arm (4).

Note: The locking handle (3) should only be

rotated towards the pump stopped for

service. The suction valve is designed to

prevent the locking handle (1) from rotating

towards the running pump, as the suction of

the running pump could cause the valve to

slam shut with sufficient force to injure the

operator and/or cause damage to the pump.

Do not attempt to circumvent this safety

feature.

3. Rotate the suction valve towards the

pump to be isolated. The orientation of the

shaft is indicated by the center pin on the

locking arm (4).

4. Loosen set screw (11) and raise the

locking handle (3) so that the cam on the

base on the handle forces the pin of the

locking arm (4) towards the pump to be

isolated. The locking handle (3) should be

raised to between 45 degrees and the vertical

position.

THIS HANDLE SHOULD NOT BE

ROTATED PAST THE VERTICAL

POSITION.

5. Tighten set screw (11) to secure the

locking handle (3) in position.

Unlocking:

1. Open the interconnecting valve on the

seal flush line to pressurize the serviced

pump and vent air through bleeder valve on

series 4302. Close these valves once the

pressure is equalized and air removed.

2. Loosen set screw (11) and lower locking

handle (3) to the horizontal position, secure

with set screw (11).

NOTE: Keep hands and tools away from

suction valve locking arm when freed by

locking handle as differential pressure may

Care should be taken when

performing procedures 3 and 4. Read

instructions carefully.

Care should be taken when

performing procedures 3 and 4. Read

instructions carefully.

WARNING

WARNING