Table 1-4 Specifications for Standard GF81 Series

*Alarm modes are dependant on the communications interface. These are described in the corresponding digital communication interface manual.

GF81

GF81

GF81

GF81

GF81

* Note: Application specific lower supply pressure and/or lower differential pressure operation available through Brooks Customer Special Request (CSR) process.

PPPPPerformance

erformance

erformance

erformance

erformance

Standar

Standar

Standar

Standar

Standard Con

d Con

d Con

d Con

d Configur

figur

figur

figur

figuration Full Scale

ation Full Scale

ation Full Scale

ation Full Scale

ation Full Scale

Flow Range (N

Flow Range (N

Flow Range (N

Flow Range (N

Flow Range (N

22222

equivlen

equivlen

equivlen

equivlen

equivlent)

t)

t)

t)

t)

51 - 300 slm

Flow

Flow

Flow

Flow

Flow Accur

Accur

Accur

Accur

Accuracy

acy

acy

acy

acy

35-100% = 1% S.P., 2-35% = 0.35% F.S.

Repeatability & Repr

Repeatability & Repr

Repeatability & Repr

Repeatability & Repr

Repeatability & Reproducibility

oducibility

oducibility

oducibility

oducibility

0.15% S.P.

Linearity

Linearity

Linearity

Linearity

Linearity

+ 0.5% F.S. (included in accuracy)

Response

Response

Response

Response

Response Time (Settling

Time (Settling

Time (Settling

Time (Settling

Time (Settling Time)

Time)

Time)

Time)

Time)

< 1 second

Con

Con

Con

Con

Contr

tr

tr

tr

trol Range

ol Range

ol Range

ol Range

ol Range

5% - 100%

VVVVValve Shut Down

alve Shut Down

alve Shut Down

alve Shut Down

alve Shut Down

<2% of Standard Configuration F.S. @ 30 N

2

psig/atm out

ZZZZZer

er

er

er

ero Stability

o Stability

o Stability

o Stability

o Stability

<±0.5% F.S. per year

Pr

Pr

Pr

Pr

Pressur

essur

essur

essur

essure Coefficien

e Coefficien

e Coefficien

e Coefficien

e Coefficienttttt

0.03% per psi (0-50psi N

2

)

AAAAAttitude Sensitivity

ttitude Sensitivity

ttitude Sensitivity

ttitude Sensitivity

ttitude Sensitivity

<0.25% span change @ 90

O

after rezeroing (N

2

@ 50 psi)

Auto Z

Auto Z

Auto Z

Auto Z

Auto Zer

er

er

er

ero:

o:

o:

o:

o:

Optional: When Auto Zero is enabled the device performs the zero function once every time the set point returns to

zero. To accomplish. simply provide a zero set point.

Auto Shut-off:

Auto Shut-off:

Auto Shut-off:

Auto Shut-off:

Auto Shut-off:

The Auto Shut-off feature closes the GF81 valve when the set point drops below 2% of full scale.

AAAAAvailable Gases:

vailable Gases:

vailable Gases:

vailable Gases:

vailable Gases:

N

2

, H

2

, Ar, He, O

2

, NH

3

(consult factory for other gases)

Ratings

Ratings

Ratings

Ratings

Ratings

Oper

Oper

Oper

Oper

Operating

ating

ating

ating

ating TTTTTemper

emper

emper

emper

emperatur

atur

atur

atur

ature Range

e Range

e Range

e Range

e Range

5-50

O

C (41-122

O

F)

Maximum Oper

Maximum Oper

Maximum Oper

Maximum Oper

Maximum Operating Pr

ating Pr

ating Pr

ating Pr

ating Pressur

essur

essur

essur

essure*

e*

e*

e*

e*

Controller: 75 psig (5 bar) / Meter: 150 psig (10 bar)

Differ

Differ

Differ

Differ

Differen

en

en

en

ential Pr

tial Pr

tial Pr

tial Pr

tial Pressur

essur

essur

essur

essure Range*

e Range*

e Range*

e Range*

e Range*

30 - 90 psid

Leak In

Leak In

Leak In

Leak In

Leak Integrity (External)

tegrity (External)

tegrity (External)

tegrity (External)

tegrity (External)

Metal Seal 1 x 10

-10

atm cc/sec He

Mec

Mec

Mec

Mec

Mechanical

hanical

hanical

hanical

hanical

VVVVValve

alve

alve

alve

alve TTTTType

ype

ype

ype

ype

Normally Closed, Meter

Primary

Primary

Primary

Primary

Primary W

W

W

W

Wetted Materials

etted Materials

etted Materials

etted Materials

etted Materials

316 Stainless Steel, Hastelloy C-22, KM45

External Seals

External Seals

External Seals

External Seals

External Seals

316 Stainless Steel

In

In

In

In

Internal Seals/V

ternal Seals/V

ternal Seals/V

ternal Seals/V

ternal Seals/Valve Seat

alve Seat

alve Seat

alve Seat

alve Seat

316 Stainless Steel

Diagnostics & Display

Diagnostics & Display

Diagnostics & Display

Diagnostics & Display

Diagnostics & Display

Status Lights:

Status Lights:

Status Lights:

Status Lights:

Status Lights:

MFC Health, Network Status

Alarms*:

Alarms*:

Alarms*:

Alarms*:

Alarms*:

Sensor Output, Control Valve Output, Over Temperature, Power Surge/Sag, Network Interruption

Diagnostic / Service P

Diagnostic / Service P

Diagnostic / Service P

Diagnostic / Service P

Diagnostic / Service Port:

ort:

ort:

ort:

ort:

RS485 via 2.5mm jack

Compliance

Compliance

Compliance

Compliance

Compliance

En

En

En

En

Envir

vir

vir

vir

vironmen

onmen

onmen

onmen

onmental Compliance:

tal Compliance:

tal Compliance:

tal Compliance:

tal Compliance:

CE: EN6126: 2006 (FCC Part 15 & Canada IC-subset of CE testing)

Safety EN61010-1

RoHS

Advertising
This manual is related to the following products: