MV-59 LINE NOTCH COUNTER

The Line Notch Counter parameter checks the integrity of the AC line. Notches on the
line are caused by inductive loads (e.g., motors, contactors) which cause the counter to
increment if the AC line is too low (soft). The Line Notch Counter displays the number
of line notches that have occurred on the AC line.

MV-80 LEAD JOB SIZE

The Lead Job Size displays the total Lead encoder lines that are registered for the most
recent job cycle.

MV-81 FOLLOWER JOB SIZE

The Follower Job Size displays the total Follower encoder lines registered for the
forward direction of the profile.

MV-84 FOLLOWER PROFILE LENGTH

The Follower Profile Length displays the calculated number of forward encoder lines for
the profile.

MV-86 PROCESS RATIO

The M–Traverse calculates and displays the commanded ratio of the Follower
Frequency to the Lead Frequency. The commanded ratio is used during the constant
pitch plateau segment of the profile.

MV-87 PROFILE RATIO

The M–Traverse displays the current commanded Follower to Lead ratio for the
immediate operation during the in-line profile execution. MV-87 and MV-86 will be the
same value during the constant pitch plateau segment of the profile.

MV-89 BATCH COUNT

The M–Traverse calculates and displays the number of completed batch counts (profile
completion).