CONTREX M-Traverse User Manual

Page 85

Advertising
background image

3 - 38

Output A activates peripheral equipment in response to the Output A parameters. This
peripheral equipment can be set up to add material (e.g., adhesive or paint) during
specific segments of the Follower profile.

Output A Segment (CP-90)

Use the Output A Segment (CP-90) parameter to determine what
segment of the Follower profile will activate Output A.

Enter “1” in CP-90 to activate Output A during the constant pitch plateau
segment of the Follower profile.
Enter “2” in CP-90 to activate Output A during the constant pitch and
Accel/Decel segments of the Follower profile.
Enter “3” in CP-90 to activate Output A during the dwell segment of the
Follower profile.

The diagram below illustrates the segments of the Follower profile :

Constant

Pitch

Plateau

Follower Profile

Accel/Decel

Accel/Decel

Dwell

1

2

3

Output A Direction (CP-91)

Use the Output A Direction (CP-91) parameter to specify the direction in
which Output A will operate.

Enter “1” in CP-91 to activate Output A during the forward direction.
Enter “2” in CP-91 to activate Output A during the reverse direction.
Enter “3” in CP-91 to activate Output A during the forward and reverse
directions.

Output A Polarity (CP-92)

Use the Output A Polarity (CP-92) parameter to specify the voltage
polarity at which Output A will operate.

Enter “0” in CP-92 to activate Output A as Active Low Voltage Level.
Enter “1” in CP-92 to activate Output A as Active High Voltage Level.