Preset parameters – CONTREX M-Traverse User Manual

Page 60

Advertising
background image

3 - 13

Preset Parameters

Setpoints (CP-01, CP-03, CP-05, CP-07)

The Setpoint parameters are set up as pairs in conjunction with the
Traverse Length parameters. There are four pairs of Setpoint and
Traverse Length parameters. The Setpoint value is entered in Engi-
neering Units (E.U.s) and automatically displays the decimal position
that was entered in the Engineering Units (CP-15). The Setpoint
parameter determines how far the Follower travels based on the Lead.
The Follower travels the setpoint distance while the Lead travels the
distance entered into CP-17. In the level wind application, the Setpoint
parameters are the laypitch (center-to-center distance between wind-
ings on the reel). In the web scanning application, the Setpoint param-
eters are the traverse length. These preset parameters can be switch
selected (via the Setpoint Select switches) which gives the operator the
option of changing over the product up to four times.

The factory defaults for the Default Setpoint Control Parameters are found in Table 3-6.
To modify the default parameters refer to Table 3-7. If you are uncertain how to enter a
Control Parameter, review the

Operations: Keypad

section.

Table 3-6 Default Setpoint Control Parameters

CP

Parameter Name

Parameter Value

CP-01

Setpoint 1

0.000

CP-03

Setpoint 2

0.000

CP-05

Setpoint 3

0.000

CP-07

Setpoint 4

0.000