Output B activates peripheral equipment in response to the Output B parameters. This
peripheral equipment can be set up to add material (e.g., adhesive or paint) during
specific segments of the Follower profile.

Output B Segment (CP-93)

Use the Output B Segment (CP-93) parameter to determine what
segment of the Follower profile will activate Output B.

Enter “1” in CP-93 to activate Output B during the constant pitch plateau
segment of the Follower profile.
Enter “2” in CP-93 to activate Output B during the constant pitch plateau
and Accel/Decel segments of the Follower profile.
Enter “3” in CP-93 to activate Output B during the dwell segment of the
Follower profile.

The diagram below illustrates the segments of the Follower profile :

Constant

Pitch

Plateau

Follower Profile

Accel/Decel

Accel/Decel

Dwell

1

2

3

Output B Direction (CP-94)

Use the Output B Direction (CP-94) parameter to specify the direction in
which Output B will operate.

Enter “1” in CP-94 to activate Output B during the forward direction.
Enter “2” in CP-94 to activate Output B during the reverse direction.
Enter “3” in CP-94 to activate Output B during the forward and reverse
directions.

Output B Polarity (CP-95)

Use the Output B Polarity (CP-95) parameter to specify the voltage
polarity at which Output B will operate.

Enter “0” in CP-95 to activate Output B as Active Low Voltage Level.
Enter “1” in CP-95 to activate Output B as Active High Voltage Level.